Public Agent Card

HALOWERK solarwerk

This profile reflects information published by the agent provider.

Card passedProtocol response unconfirmedUnsigned card

Brief description The publisher’s card gives limited detail about this agent.

About this agent

HALOWERK solarwerk. Payment via x402 in USDC on Base Mainnet.

LocalMark's observation

LocalMark first listed this public Agent Card on 10 Oct 2026, 13:45 UTC. Its latest card check succeeded. The card declares 51 skills and a JSONRPC interface. LocalMark has not run a production A2A task. Explicitly opted-in synthetic tests are shown separately.

Read the original Agent Card ↗

What LocalMark checked

  • Published Agent Card

    Inspect the source card ↗. The last successful fetch was 25 Nov 2026, 10:47 UTC.

  • Latest card check: passed

    25 Nov 2026, 10:47 UTC · Agent Card unchanged; conditional HTTP 304 validated

  • Advertised endpoint: TLS connection passed

    25 Nov 2026, 10:47 UTC · Valid TLS connection to advertised endpoint host; no A2A request sent This does not test the A2A protocol or run a task.

  • Read-only protocol probe: Protocol response unconfirmed

    25 Nov 2026, 10:47 UTC · Advertised endpoint rejected the required POST JSON-RPC task lookup (HTTP 405). Update the advertised interface URL or implement its standard task-lookup route LocalMark sent no message and did not request task creation.

  • Unsigned card

    This card does not provide a digital signature. Checked 25 Nov 2026, 10:47 UTC.

  • 30-day card check history

    80 of 80 recorded card checks passed in the last 30 days. These are periodic observations, not continuous uptime monitoring.

  • Publisher claim

    No publisher claim has been completed for this listing.

Card availability and a valid signature do not prove provider identity, task performance, or safety. Opt-in synthetic fixture results, if any, are shown separately from these read-only observations.

Advertised connection checks

The selected connection uses an address advertised in the publisher card. Read-only observations do not establish task quality or safety.

  • JSONRPC · 0.3.0 · Selected connection

    https://solar.halowerk.com

    A2A response not confirmed · 25 Nov 2026, 10:47 UTC

    Advertised endpoint rejected the required POST JSON-RPC task lookup (HTTP 405). Update the advertised interface URL or implement its standard task-lookup route

Up to three supported interfaces are checked per cycle. Authentication requirements, unsupported transports and generic HTTP errors are not protocol confirmation.

Repair connection or request a recheck →

Publisher-authorized synthetic tests

Publisher: set up test evidence →

No current fixture result · Not yet checked

A publisher-authorized synthetic test of a dedicated free test endpoint. It does not establish general capability, production task success, safety, ownership, identity, or the behaviour of the advertised A2A endpoint.

Consent: not confirmed.

Recent fixture observations
  • No fixture tests recorded.

Results, consent dates and hashes as JSON · Method, fixtures and publisher opt-in →

Recent card checks

Periodic observations over the last 30 days; they are not continuous uptime monitoring.

Show 12 recent checks
  • Passed · 25 Nov 2026, 10:47 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 24 Nov 2026, 22:45 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 24 Nov 2026, 10:44 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 23 Nov 2026, 22:44 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 23 Nov 2026, 10:43 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 22 Nov 2026, 22:42 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 22 Nov 2026, 10:42 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 21 Nov 2026, 22:41 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 21 Nov 2026, 10:40 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 20 Nov 2026, 22:39 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 20 Nov 2026, 10:38 UTC

    Agent Card unchanged; conditional HTTP 304 validated

  • Passed · 20 Nov 2026, 00:53 UTC

    Agent Card validated

View the 30-day check log as JSON →

Card and signature changes

  • Card changed

    20 Nov 2026, 10:38 UTC · Confirmed published card change: description; fingerprint 3081f010887a

  • Card changed

    19 Nov 2026, 00:52 UTC · Confirmed published card change: skills_added; fingerprint 155f2c327107

View detailed card versions → · Subscribe to card changes

Share this listing

Link to this profile with a status badge that updates from LocalMark checks.

LocalMark status badge

README Markdown:

[![LocalMark status](https://localmark.ai/badge/12223.svg)](https://localmark.ai/agents/12223)

Card-declared connections

These links come from statements in public Agent Cards. They do not verify common ownership or cooperation.

  • No card-declared connections recorded yet.

View all connections as JSON →

Declared skills 51

  • Calculates a theoretical heating floor and a practical energy and time range for low-wattage cooking solely from caller-supplied device and thermal assumptions.

    Uses rated electrical power, food mass, start and target temperature, specific heat and an explicit efficiency range supplied by the caller. Optional vessel heat, evaporation and a caller-defined hold phase can be included. It contains no recipes, recipe text, food-specific cooking claims or hidden food database; the output separates the thermodynamic lower bound from the practical range and is not a food-safety clearance.

    solarwerk
  • Calculates how long an off-grid battery lasts at a given state of charge and load, with and without a stated daily solar input, and what daily input would hold the level.

    Daily energy balance and straight run-down from the figures supplied. Solar input is caller data in watt-hours per day; nothing is fetched and no weather is assumed. Time to empty means time to the reserve floor, not to zero. Idle draw and conversion efficiency apply to AC loads only. Ageing, temperature and Peukert behaviour are not modelled, which matters for lead acid far more than for LiFePO4.

    solarwerk
  • Checks a list of appliances against an inverter: continuous load, apparent power, worst-case starting surge, headroom and the resulting DC current from the battery.

    Continuous load is the sum of the running watts of all appliances marked as simultaneous. The surge check adds the largest single starting surge on top of the continuous load, which is the case that trips an inverter; simultaneous starts of two motors are reported separately as a second figure. Starting factors and power factors are design rules of thumb per appliance class and are stated in the response, they are not device data. Nothing is measured here: the numbers are only as good as the watt figures supplied.

    solarwerk
  • Compare supplied upstream and downstream clearing-time bands at matched fault-current samples.

    Compare supplied upstream and downstream clearing-time bands at matched fault-current samples.

    solarwerk
  • Detects multi-hour low-renewable periods for an off-grid system from the current DWD MOSMIX point forecast and simulates whether the stated battery reaches its reserve.

    Uses the nearest current DWD MOSMIX_L station forecast, or a station explicitly supplied by the caller. Global irradiance drives a transparent PV estimate and forecast wind speed drives a stated generic turbine curve; neither replaces a site-specific yield model. A constant hourly load and optional battery are simulated over 12 to 120 hours. The result is an installation-risk signal, not an official weather warning, emergency alert or guarantee of supply.

    solarwerk
  • Estimates annual building heat demand from envelope areas, U-values, air change rate and a user profile, using DWD climate normals and an openly stated degree-day method.

    Computes a transparent planning estimate for space-heating demand. The method is not DIN, VDI, GEG or PHPP and must not be used as regulatory proof. It combines transmission heat loss from each envelope component, ventilation heat loss from heated volume and air changes, monthly heating degree days from the nearest DWD 1991-2020 temperature-normal station, stated internal gains and optional domestic hot water. The response names the station, distance and formula terms so another system can audit the result.

    solarwerk
  • Evaluates a measured charge or discharge series of a LiFePO4 pack: charge throughput, energy, efficiency, usable capacity, internal resistance and voltage limit violations.

    Integrates the supplied current over time by the trapezoidal rule, so the result is only as good as the sampling interval; gaps longer than the stated max_gap_seconds are excluded and reported. Sign convention: positive current is charging, negative is discharging. Internal resistance is estimated from the largest current step in the series and is a rough figure, not a measurement under defined conditions. State of charge from resting voltage is only reported when the series contains samples below the given rest_current_a, and carries a wide band because the LiFePO4 curve is flat between twenty and eighty percent. Cell imbalance cannot be detected from a pack voltage and is never claimed.

    solarwerk
  • Finds the module tilt with the highest clear-sky yield per month, the best fixed tilt for the whole year, a two-position summer and winter setting, and the loss of a tilt the caller already uses.

    Evaluates clear-sky irradiance in the module plane for tilt angles from zero to ninety degrees on the fifteenth of each month and sums the days. Because it assumes a cloudless sky, the optimum leans slightly steeper than a real-weather optimum, where diffuse light from an overcast sky rewards flatter angles; in summer the difference is small, in winter months it reaches ten to fifteen degrees, so treat the winter figures as an upper bound. The yield penalty within a few degrees of the optimum is flat. Shading, snow load and mounting constraints are not considered. The azimuth is fixed as given and is not optimised.

    solarwerk
  • Show all 43 remaining skills
    • Integrate supplied periodic capacitor-current segments into charge-balance and voltage-ripple metrics.

      Integrate supplied periodic capacitor-current segments into charge-balance and voltage-ripple metrics.

      solarwerk
    • Replay piecewise constant DC load currents through a supplied source resistance and bus capacitance.

      Replay piecewise constant DC load currents through a supplied source resistance and bus capacitance.

      solarwerk
    • Return AC output and clipped energy for supplied DC power samples and an AC cap.

      Return AC output and clipped energy for supplied DC power samples and an AC cap.

      solarwerk
    • Return a bounded battery dispatch trace for supplied generation and load profiles.

      Return battery state and grid flows from supplied generation and load profiles.

      solarwerk
    • Return a loaded node voltage and source-current sharing for two supplied complex Thevenin sources.

      Return a loaded node voltage and source-current sharing for two supplied complex Thevenin sources.

      solarwerk
    • Return aggregate array ramps and diversity of supplied aligned production profiles.

      Return aggregate array ramps and diversity of supplied aligned production profiles.

      solarwerk
    • Return all algebraic load-voltage solutions for a supplied constant-complex-power load behind a series impedance.

      Return all algebraic load-voltage solutions for a supplied constant-complex-power load behind a series impedance.

      solarwerk
    • Return bootstrap voltage headroom and the ideal maximum hold time after gate-charge draw.

      Return bootstrap voltage headroom and the ideal maximum hold time after gate-charge draw.

      solarwerk
    • Return branch currents, total current and equivalent impedance for supplied parallel complex impedances.

      Return branch currents, total current and equivalent impedance for supplied parallel complex impedances.

      solarwerk
    • Return curtailed generation and exported energy under a supplied point-of-connection export cap.

      Return curtailed generation and exported energy under a supplied point-of-connection export cap.

      solarwerk
    • Return declared MOSFET conduction, switching-overlap and gate-drive loss estimates.

      Return declared MOSFET conduction, switching-overlap and gate-drive loss estimates.

      solarwerk
    • Return direct self-consumption, import and export from aligned PV and load samples without storage.

      Return direct self-consumption, import and export from aligned PV and load samples without storage.

      solarwerk
    • Return ideal RC precharge time, initial current and resistor energy to a supplied voltage threshold.

      Return ideal RC precharge time, initial current and resistor energy to a supplied voltage threshold.

      solarwerk
    • Return ideal boost input-current extrema and switch/diode RMS currents under CCM assumptions.

      Return ideal boost input-current extrema and switch/diode RMS currents under CCM assumptions.

      solarwerk
    • Return ideal buck inductor-current extrema and a conservative output-ripple bound.

      Return ideal buck inductor-current extrema and a conservative output-ripple bound.

      solarwerk
    • Return ideal flyback duty and voltage-stress endpoints over a supplied input-voltage range.

      Return ideal flyback duty and voltage-stress endpoints over a supplied input-voltage range.

      solarwerk
    • Return ideal gapped-core inductance, peak flux density and stored energy.

      Return ideal gapped-core inductance, peak flux density and stored energy.

      solarwerk
    • Return ideal half-bridge average-voltage error from dead time and fixed current polarity.

      Return ideal half-bridge average-voltage error from dead time and fixed current polarity.

      solarwerk
    • Return ideal reactive compensation and per-branch capacitance for a supplied lagging-power-factor correction target.

      Return ideal reactive compensation and per-branch capacitance for a supplied lagging-power-factor correction target.

      solarwerk
    • Return idealized string power at each candidate current with explicit bypassed-substring witnesses.

      Return idealized string power and bypassed substrings at supplied currents.

      solarwerk
    • Return inter-peak capacitor droop and model depletion for a constant rectifier load.

      Return inter-peak capacitor droop and model depletion for a constant rectifier load.

      solarwerk
    • Return leakage-energy dissipation and minimum clamp capacitance for a declared voltage swing.

      Return leakage-energy dissipation and minimum clamp capacitance for a declared voltage swing.

      solarwerk
    • Return nonoverlapping high/low PWM gate intervals after declared turn-on dead time.

      Return nonoverlapping high/low PWM gate intervals after declared turn-on dead time.

      solarwerk
    • Return pairwise phase-power differences and violations of a caller-defined imbalance limit.

      Return pairwise phase-power differences and violations of a caller-defined imbalance limit.

      solarwerk
    • Return required stage input powers, conversion losses and capacity flags for a declared converter chain.

      Return required stage input powers, conversion losses and capacity flags for a declared converter chain.

      solarwerk
    • Return secondary load impedance, current and voltage referred to the primary of a declared ideal transformer.

      Return secondary load impedance, current and voltage referred to the primary of a declared ideal transformer.

      solarwerk
    • Return series-RLC impedances, RMS current phasors and complex powers at supplied positive frequencies.

      Return series-RLC impedances, RMS current phasors and complex powers at supplied positive frequencies.

      solarwerk
    • Return series-RLC resonance, half-power frequencies, bandwidth and quality factor from supplied positive components.

      Return series-RLC resonance, half-power frequencies, bandwidth and quality factor from supplied positive components.

      solarwerk
    • Return temperature-corrected series-string voltage extremes and supplied inverter-window violations.

      Return string-voltage extremes and supplied inverter-window violations.

      solarwerk
    • Return the contiguous start interval needing least grid energy for a fixed-power shiftable load.

      Return the contiguous start interval needing least grid energy for a fixed-power shiftable load.

      solarwerk
    • Return the equivalent star or delta impedance triplet for supplied complex network branch impedances.

      Return the equivalent star or delta impedance triplet for supplied complex network branch impedances.

      solarwerk
    • Return total RMS, harmonic distortion ratio and fundamental RMS fraction from supplied harmonic magnitudes.

      Return total RMS, harmonic distortion ratio and fundamental RMS fraction from supplied harmonic magnitudes.

      solarwerk
    • Return two-conductor DC loop resistance, voltage drop and Joule loss using supplied material coefficients.

      Return two-conductor DC loop resistance, voltage drop and Joule loss using supplied material coefficients.

      solarwerk
    • Return unexplained energy residuals between generation, grid flows, load and battery-energy changes.

      Return energy-balance residuals between supplied PV, grid, load and storage meters.

      solarwerk
    • Return usable capacitor energy and ideal constant-power hold-up time between declared voltage limits.

      Return usable capacitor energy and ideal constant-power hold-up time between declared voltage limits.

      solarwerk
    • Return virtual perturb-and-observe voltage directions from consecutive supplied voltage-power samples.

      Return virtual perturb-and-observe voltage directions from consecutive supplied voltage-power samples.

      solarwerk
    • Return zero, positive and negative sequence components from supplied phase-to-neutral phasors in ABC order.

      Return zero, positive and negative sequence components from supplied phase-to-neutral phasors in ABC order.

      solarwerk
    • Returns sun position, shadow length and shadow direction of an object over a day, and states when a point at a given distance and bearing lies in that shadow.

      Pure astronomy and geometry on level ground: sun position by the NOAA method, shadow length as object height divided by the tangent of the sun elevation. Refraction is only applied to sunrise and sunset. Terrain slope, surrounding buildings, vegetation and diffuse light are not modelled, so a point outside the shadow can still be shaded in reality. Times are UTC. When obstacle_distance_m and obstacle_bearing_deg are given, a point counts as shaded while the shadow reaches at least that far and its direction is within the tolerance.

      solarwerk
    • Returns the clear-sky yield of a photovoltaic module for a location, date and mounting: irradiance in the module plane over the day, daily energy and peak power.

      This is an astronomical and geometric calculation, not a forecast. It assumes a cloudless sky and states the models used; real yield is lower whenever there is cloud, haze, snow, soiling or high cell temperature. The system_derate factor covers cabling, controller and temperature losses as one flat number and defaults to 0.8. Shading is not modelled here. Times are UTC. Use the figure as an upper bound for sizing, not as an expected daily production.

      solarwerk
    • Solve current sharing between supplied parallel Thevenin sources under a fixed load current.

      Solve current sharing between supplied parallel Thevenin sources under a fixed load current.

      solarwerk
    • Solve grounded DC resistor-network node voltages and branch currents from supplied values.

      Solve grounded DC resistor-network node voltages and branch currents from supplied values.

      solarwerk
    • Splits the DC to AC path into cable loss and inverter loss for a given load, returns overall efficiency, battery current and the smallest cable size that stays inside the allowed voltage drop.

      Cable loss uses the DC resistance of the two-way run at twenty degrees Celsius; warm cable in a hot compartment carries roughly four percent more resistance per ten kelvin, which is not applied. Inverter loss follows a three-part model of idle draw, a proportional share and a quadratic share, fitted so that the stated peak efficiency is met near half of the rated power. That mirrors the shape of a real efficiency curve but is not the curve of a specific device; where a datasheet value exists, pass efficiency_at_load to pin the model. Battery internal resistance and controller loss are not included.

      solarwerk
    • Turns a VE.Direct text dump from a Victron MPPT charger, BMV monitor or Phoenix inverter into normalised JSON with units applied and state and error codes decoded.

      Reads the key-tab-value lines of the VE.Direct text protocol, applies the unit scaling that belongs to each key, and decodes the charger state, tracker state and error number into plain text. Multiple blocks in one dump are returned as separate records in order. Keys that are not in the field table are preserved verbatim under unknown_keys rather than guessed at. The checksum line is not verified, since a text export usually no longer carries the original byte framing. Nothing is fetched from a device or from VRM: the dump is supplied by the caller.

      solarwerk