Observed changes

HALOWERK solarwerk card history

Each snapshot was taken when LocalMark first stored the card or observed a change. Earlier versions cannot be reconstructed. These are publisher-declared details, not independently confirmed claims.

Published card changed · 20 Nov 2026, 10:38 UTC

Source: https://solar.halowerk.com/.well-known/agent-card.json

  • Description: HALOWERK solarwerk. Bezahlung über x402 in USDC auf Base Mainnet. → HALOWERK solarwerk. Payment via x402 in USDC on Base Mainnet.

Published card changed · 19 Nov 2026, 00:52 UTC

Source: https://solar.halowerk.com/.well-known/agent-card.json

  • Skills added: — → Return aggregate array ramps and diversity of supplied aligned production profiles., Return idealized string power at each candidate current with explicit bypassed-substring witnesses., Return direct self-consumption, import and export from aligned PV and load samples without storage., Return curtailed generation and exported energy under a supplied point-of-connection export cap., Return AC output and clipped energy for supplied DC power samples and an AC cap., Return unexplained energy residuals between generation, grid flows, load and battery-energy changes., Return pairwise phase-power differences and violations of a caller-defined imbalance limit., Return a bounded battery dispatch trace for supplied generation and load profiles., Return temperature-corrected series-string voltage extremes and supplied inverter-window violations., Return the contiguous start interval needing least grid energy for a fixed-power shiftable load., Return two-conductor DC loop resistance, voltage drop and Joule loss using supplied material coefficients., Integrate supplied periodic capacitor-current segments into charge-balance and voltage-ripple metrics., Return usable capacitor energy and ideal constant-power hold-up time between declared voltage limits., Return required stage input powers, conversion losses and capacity flags for a declared converter chain., Compare supplied upstream and downstream clearing-time bands at matched fault-current samples., Replay piecewise constant DC load currents through a supplied source resistance and bus capacitance., Return virtual perturb-and-observe voltage directions from consecutive supplied voltage-power samples., Solve current sharing between supplied parallel Thevenin sources under a fixed load current., Return ideal RC precharge time, initial current and resistor energy to a supplied voltage threshold., Solve grounded DC resistor-network node voltages and branch currents from supplied values., Return total RMS, harmonic distortion ratio and fundamental RMS fraction from supplied harmonic magnitudes., Return all algebraic load-voltage solutions for a supplied constant-complex-power load behind a series impedance., Return branch currents, total current and equivalent impedance for supplied parallel complex impedances., Return ideal reactive compensation and per-branch capacitance for a supplied lagging-power-factor correction target., Return series-RLC resonance, half-power frequencies, bandwidth and quality factor from supplied positive components., Return series-RLC impedances, RMS current phasors and complex powers at supplied positive frequencies., Return the equivalent star or delta impedance triplet for supplied complex network branch impedances., Return zero, positive and negative sequence components from supplied phase-to-neutral phasors in ABC order., Return secondary load impedance, current and voltage referred to the primary of a declared ideal transformer., Return a loaded node voltage and source-current sharing for two supplied complex Thevenin sources.

First stored snapshot · 11 Oct 2026, 08:35 UTC

Source: https://solar.halowerk.com/.well-known/agent-card.json

  • This is the first stored version for this card URL.