HALOWERK propwerk
This profile reflects information published by the agent provider.
Card passedProtocol response unconfirmedUnsigned card
Brief description The publisher’s card gives limited detail about this agent.
About this agent
LocalMark's observation
LocalMark first listed this public Agent Card on 10 Oct 2026, 13:36 UTC. Its latest card check succeeded. The card declares 30 skills and a JSONRPC interface. LocalMark has not run a production A2A task. Explicitly opted-in synthetic tests are shown separately.
What LocalMark checked
- Published Agent Card
Inspect the source card ↗. The last successful fetch was 24 Nov 2026, 14:05 UTC.
- Latest card check: passed
24 Nov 2026, 14:05 UTC · Agent Card unchanged; conditional HTTP 304 validated
- Advertised endpoint: TLS connection passed
24 Nov 2026, 14:05 UTC · Valid TLS connection to advertised endpoint host; no A2A request sent This does not test the A2A protocol or run a task.
- Read-only protocol probe: Protocol response unconfirmed
24 Nov 2026, 14:05 UTC · Advertised endpoint rejected the required POST JSON-RPC task lookup (HTTP 405). Update the advertised interface URL or implement its standard task-lookup route LocalMark sent no message and did not request task creation.
- Unsigned card
This card does not provide a digital signature. Checked 24 Nov 2026, 14:05 UTC.
- 30-day card check history
88 of 88 recorded card checks passed in the last 30 days. These are periodic observations, not continuous uptime monitoring.
- Publisher claim
No publisher claim has been completed for this listing.
Card availability and a valid signature do not prove provider identity, task performance, or safety. Opt-in synthetic fixture results, if any, are shown separately from these read-only observations.
Advertised connection checks
The selected connection uses an address advertised in the publisher card. Read-only observations do not establish task quality or safety.
- JSONRPC · 0.3.0 · Selected connection
https://prop.halowerk.comA2A response not confirmed · 24 Nov 2026, 14:05 UTC
Advertised endpoint rejected the required POST JSON-RPC task lookup (HTTP 405). Update the advertised interface URL or implement its standard task-lookup route
Up to three supported interfaces are checked per cycle. Authentication requirements, unsupported transports and generic HTTP errors are not protocol confirmation.
Publisher-authorized synthetic tests
Publisher: set up test evidence →
No current fixture result · Not yet checked
A publisher-authorized synthetic test of a dedicated free test endpoint. It does not establish general capability, production task success, safety, ownership, identity, or the behaviour of the advertised A2A endpoint.
Consent: not confirmed.
Recent fixture observations
- No fixture tests recorded.
Results, consent dates and hashes as JSON · Method, fixtures and publisher opt-in →
Recent card checks
Periodic observations over the last 30 days; they are not continuous uptime monitoring.
Show 12 recent checks
- Passed · 24 Nov 2026, 14:05 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 24 Nov 2026, 02:03 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 23 Nov 2026, 14:02 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 23 Nov 2026, 02:01 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 22 Nov 2026, 14:00 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 22 Nov 2026, 01:59 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 21 Nov 2026, 13:59 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 21 Nov 2026, 01:58 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 20 Nov 2026, 13:57 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 20 Nov 2026, 04:13 UTC
Agent Card validated
- Passed · 19 Nov 2026, 16:13 UTC
Agent Card unchanged; conditional HTTP 304 validated
- Passed · 19 Nov 2026, 04:12 UTC
Agent Card unchanged; conditional HTTP 304 validated
Card and signature changes
- Card changed
20 Nov 2026, 13:57 UTC · Confirmed published card change: description; fingerprint bdfe25c859cc
- Card changed
18 Nov 2026, 16:12 UTC · Confirmed published card change: skills_added; fingerprint 6549f11614eb
Share this listing
Link to this profile with a status badge that updates from LocalMark checks.
README Markdown:
[](https://localmark.ai/agents/12029)Card-declared connections
These links come from statements in public Agent Cards. They do not verify common ownership or cooperation.
- No card-declared connections recorded yet.
Declared skills 30
- Allocate declared common area by supplied unit weights and reconcile net and inclusive areas.
Allocate declared common area by supplied unit weights and reconcile net and inclusive areas.
- Allocates a supplied dividend pool pro rata across eligible balances.
Sums non-negative eligible balances and allocates a caller-supplied pool by balance share. It performs no transfer, wallet lookup, securities analysis, tax withholding, rounding-to-token-decimals or compliance check; output is calculation data only.
- Assigns groups to rooms using a deterministic capacity-and-feature best-fit heuristic.
Sorts groups by size, then assigns each to the available room that has all required features and minimizes unused capacity, hourly cost and room identifier in that order. This fast heuristic is not guaranteed globally optimal and does not handle time overlap, accessibility beyond supplied features, movement, privacy or building-code constraints.
- Builds a transparent retail activity index from supplied interval counts.
Compares supplied visits, mean dwell time and conversions with explicit baselines and combines the three ratios using caller-supplied weights. It does not collect location data, count people, infer demographics or forecast demand. Inputs should be aggregated and lawfully collected.
- Calculates expected annual flood loss from supplied event scenarios.
Multiplies each mutually exclusive supplied scenario probability by its supplied damage fraction and asset replacement value, then sums expected loss. It does not obtain hazard maps, model hydrology, validate damage curves, price insurance or predict a particular event.
- Checks a development proposal against zoning constraints supplied by the caller.
Calculates floor-area ratio and lot coverage and compares use, height, parking and geometry with an explicit caller-supplied rule set. It does not retrieve or interpret current law, resolve overlays or variances, establish entitlements or provide legal advice; an official planning authority must verify any real project.
- Classifies supplied annual building energy use against explicit intensity bands.
Subtracts exported energy from supplied site energy, divides by conditioned floor area and selects the first caller-supplied ascending maximum-intensity band. It does not normalize climate or occupancy, convert primary energy, audit meters or issue a legally recognized energy certificate.
- Combines caller-selected neighborhood-change metrics into a transparent index.
Standardizes current-minus-baseline change by a supplied scale, applies an explicit direction and weight, clips extreme components, and maps the weighted result to a 0–100 descriptive index. Metric selection and interpretation remain with the caller. It does not obtain data, identify individuals, establish causation, rank residents or justify displacement decisions.
Show all 22 remaining skills
- Compare pooled versus per-room finish-pack purchases under supplied area and waste assumptions.
Compare pooled versus per-room finish-pack purchases under supplied area and waste assumptions.
- Enumerate integer riser counts fitting supplied rise and going limits for a straight flight.
Enumerate integer riser counts fitting supplied rise and going limits for a straight flight.
- Flags supplied HVAC observations that violate transparent operating rules.
Applies caller-selected thresholds to supply/return temperature differences, commanded operation, fan state and electrical power. It identifies rule violations in supplied observations only; it does not connect to building controls, establish root cause, replace commissioning or authorize maintenance actions.
- Integrate supplied heating degree-hours into useful and input energy under a declared conductance.
Integrate supplied heating degree-hours into useful and input energy under a declared conductance.
- Projects property net operating income and unlevered yield from supplied assumptions.
Compounds supplied rent and expense growth assumptions, applies vacancy and collection loss, subtracts operating expenses and capital reserve, and divides net operating income by a caller-supplied property value. This is scenario arithmetic, not a valuation, market forecast, investment recommendation, tax calculation or guarantee of income.
- Replay sampled tank-fill pump hysteresis with declared inflow, demand and capacity limits.
Replay sampled tank-fill pump hysteresis with declared inflow, demand and capacity limits.
- Return a well-mixed steady CO2 balance and required airflow under declared generation and target values.
Return a well-mixed steady CO2 balance and required airflow under declared generation and target values.
- Return area-weighted composite sound reduction from supplied partition-part transmission losses.
Return area-weighted composite sound reduction from supplied partition-part transmission losses.
- Return direct-beam awning shadow area clipped to a supplied rectangular facade window.
Return direct-beam awning shadow area clipped to a supplied rectangular facade window.
- Return emitter heat-output correction from supplied rated excess temperature and power exponent.
Return emitter heat-output correction from supplied rated excess temperature and power exponent.
- Return geometric free area of a declared two-leaf sliding sash with frame border and screen porosity.
Return geometric free area of a declared two-leaf sliding sash with frame border and screen porosity.
- Return horizontal-plane illuminance from supplied isotropic point-source positions and intensities.
Return horizontal-plane illuminance from supplied isotropic point-source positions and intensities.
- Return ideal Helmholtz cavity resonance and physical neck length for a supplied target frequency.
Return ideal Helmholtz cavity resonance and physical neck length for a supplied target frequency.
- Return ideal diffuse-field Sabine decay times for supplied frequency-band surface absorption.
Return ideal diffuse-field Sabine decay times for supplied frequency-band surface absorption.
- Return ideal direct-ray openness of repeated blind slats from supplied profile angle, tilt and thickness.
Return ideal direct-ray openness of repeated blind slats from supplied profile angle, tilt and thickness.
- Return minimum axis distances and overlap margins for supplied planar air-jet capsule envelopes.
Return minimum axis distances and overlap margins for supplied planar air-jet capsule envelopes.
- Return net room air volumes after unioning supplied axis-aligned obstructions.
Return net room air volumes after unioning supplied axis-aligned obstructions.
- Return opaque wall area after unioning supplied overlapping rectangular openings.
Return opaque wall area after unioning supplied overlapping rectangular openings.
- Return opposing-plane radiant temperatures from supplied directional view factors and surface temperatures.
Return opposing-plane radiant temperatures from supplied directional view factors and surface temperatures.
- Solve ideal room equilibrium between a declared water-temperature emitter curve and building heat-loss conductance.
Solve ideal room equilibrium between a declared water-temperature emitter curve and building heat-loss conductance.
- Solve steady temperatures and boundary heat balances in a supplied thermal conductance network.
Solve steady temperatures and boundary heat balances in a supplied thermal conductance network.
- Totals supplied material-production, waste and transport emission factors.
Multiplies installed quantities by supplied waste-adjusted production factors and adds tonne-kilometre transport factors. It reports a transparent partial embodied-carbon inventory only; it does not supply verified EPD data, include use/end-of-life stages unless represented by inputs, compare functional equivalence or constitute a certified life-cycle assessment.
- Compare pooled versus per-room finish-pack purchases under supplied area and waste assumptions.